logo
GREAT SYSTEM INDUSTRY CO. LTD
E-Mail-Adresse jim@greatsystem.cn TELEFON: 852--3568 3659
Zu Hause > produits > Emerson Rosemount Drucktransmitter >
Messgerät Emerson Rosemount Druckübertrager, 3051CG Differenzdruckübertrager
  • Messgerät Emerson Rosemount Druckübertrager, 3051CG Differenzdruckübertrager
  • Messgerät Emerson Rosemount Druckübertrager, 3051CG Differenzdruckübertrager

Messgerät Emerson Rosemount Druckübertrager, 3051CG Differenzdruckübertrager

Place of Origin Singapore
Markenname Emerson Rosemount
Zertifizierung ROHS
Model Number 3051CG4A04A1AH2B3M5T1DFQ4
Einzelheiten zum Produkt
Origin:
Singapore
Model:
3051CG4A04A1AH2B3M5T1DFQ4
Power:
4-20 mA: 10.5-55 V dc with no load Low Power: 6-12 V dc with no load
Materials:
Sensor Wetted Parts: SST, Hastelloy, Monel, Tantalum, Gold Plated SS, Gold Plated Monel
Mounting:
Coplanar and Traditional flanges and Adapters: Cadmium and Nickel-plated CS, 316 SST
Measures absolute pressure:
up to 4000 psia (275.8 bar).
Measures differential and gage pressure:
up to 2000 psi (137.9 bar)
Output:
4—20ma,with HART agreement digital signal
Diaphragm Material:
316L stainless steel
Hervorheben: 

Gauge Emerson Rosemount Pressure Transmitter

,

137.9 bar Emerson Rosemount Pressure Transmitter

,

3051CG Differential Pressure Level Transmitter

Zahlungs- und Versandbedingungen
Minimum Order Quantity
1
Preis
negotiable
Packaging Details
carton
Delivery Time
on request
Payment Terms
T/T
Supply Ability
1~1000pcs
Beschreibung des Produkts

Emerson Rosemount 3051cg Messdrucksender3051CG4A04A1AH2B3M5T1DFQ4

 

Beschreibung:


Hersteller: Rosemount

Produkt Nr.: 3051CG4A04A1AH2B3M5T1DFQ4

Produkttyp: Coplanar -Drucksender

Messtyp: G = Gage

Druckbereich: 4 = –300 bis 300 psi (–20,68 bis 20,68 bar)

Senderausgabe: a = 4–20 mA mit digitalem Signal basierend auf dem HART® -Protokoll

Konstruktionsmaterialien: 0 = alternative Prozessverbindung

Membran isolieren: 2 = 316L SST

O-Ring: A = mit Glas gefüllter PTFE

Sensorfüllflüssigkeit: 1 = Silikon

A

Wohnmaterial: Aluminium

Eintrittsgröße von Leitungen: ½–14 npt

Verteilerbaugruppe: S5 = Montage zu Rosemount 305 Integraler Verteiler

15

Optionen für Anzeigen und Schnittstellen: M5 = LCD -Anzeige

Kalibrierungszertifikat: Q4 = Kalibrierungszertifikat

Gewicht: 2,7 kg + 0,2 kg = 2,9 kg

Versandgewicht: 4 kg

 

 

 

Zusätzliche Information:

Der Rosemount 3051C -Smart -Druck -Sender ist in der Lage, differenzieren, mess- oder absolute Druckmessungen. Die Verwendung fortschrittlicher Kapazitätssensortechnologie (Piezoresistive Sensoren für Absolutdruckmodelle) ist der Rosemount 3051C-Smart-Druck-Transmitter bis zu ± 0,04% genau, was zu einer Gesamtbetriebsleistung führt.

 

 

Spezifikationen des Rosemount 3051Cg -Messdrucksenders

3051CD -Differenzdrucksender

3051 cg Gage Drucksender

3051CA Absolutdrucksender

 

 

Gemeinsame Modelle:

 

3051CG1A02A1AB1H2L4M5, 3051CD0A02A1AB3H2L4M5E5,
3051CG2A02A1AB1H2L4M5, 3051CD1A02A1AB3H2L4M5E5,
3051CG3A02A1AB1H2L4M5, 3051CD2A02A1AB3H2L4M5E5,
3051CG4A02A1AB1H2L4M5, 3051CD3A02A1AB3H2L4M5E5,
3051CG5A02A1AB1H2L4M5, 3051CD4A02A1AB3H2L4M5E5,
051CG1A02A1AB3H2L4M5, 3051CD5A02A1AB3H2L4M5E5,
3051CG2A02A1AB3H2L4M5, 3051CD0A02A1AB3H2L4M5I5,
3051CG3A02A1AB3H2L4M5, 3051CD1A02A1AB3H2L4M5I5,
3051CG4A02A1AB3H2L4M5, 3051CD2A02A1AB3H2L4M5I5,
3051CG5A02A1AB3H2L4M5, 3051CD3A02A1AB3H2L4M5I5,
3051CG1A02A1AB1H2L4M5K5, 3051CD4A02A1AB3H2L4M5I5,
3051CG2A02A1AB1H2L4M5K5, 3051CD5A02A1AB3H2L4M5I5,
3051CG3A02A1AB1H2L4M5K5 3051CD1A22A1AB4M5,
3051CG4A02A1AB1H2L4M5K5, 3051CD2A22A1AB4M5,
3051CG5A02A1AB1H2L4M5K5 3051CD3A22A1AB4M5,
3051CG1A02A1AB1H2L4M5E5, 3051CD4A22A1AB4M5,
3051CG2A02A1AB1H2L4M5E5, 3051CD5A22A1AB4M5,
3051CG3A02A1AB1H2L4M5E5, 3051CD1A22A1AB4M5DF,
3051CG4A02A1AB1H2L4M5E5, 3051CD2A22A1AB4M5DF,
3051CG5A02A1AB1H2L4M5E5, 3051CD3A22A1AB4M5DF,
3051CG1A02A1AB1H2L4M5I5, 3051CD4A22A1AB4M5DF,
3051CG2A02A1AB1H2L4M5I5, 3051CD5A22A1AB4M5DF,
3051CG3A02A1AB1H2L4M5I5, 3051CD1A22A1AB4M5K5,
3051CG4A02A1AB1H2L4M5I5, 3051CD2A22A1AB4M5K5,
3051CG5A02A1AB1H2L4M5I5, 3051CD3A22A1AB4M5K5,
3051CG1A02A1AB3H2L4M5K5, 3051CD4A22A1AB4M5K5,
3051CG2A02A1AB3H2L4M5K5, 3051CD5A22A1AB4M5K5,
3051CG3A02A1AB3H2L4M5K5, 3051CD1A22A1AB4M5E5,
3051CG4A02A1AB3H2L4M5K5, 3051CD2A22A1AB4M5E5,
3051CG5A02A1AB3H2L4M5K5, 3051CD3A22A1AB4M5E5,
3051CG1A02A1AB3H2L4M5E5, 3051CD4A22A1AB4M5E5,
3051CG2A02A1AB3H2L4M5E5, 3051CD5A22A1AB4M5E5,
3051CG3A02A1AB3H2L4M5E5, 3051CD1A22A1AB4M5I5,
3051CG4A02A1AB3H2L4M5E5, 3051CD2A22A1AB4M5I5,
3051CG5A02A1AB3H2L4M5E5, 3051CD3A22A1AB4M5I5,
3051CG1A02A1AB3H2L4M5I5, 3051CD4A22A1AB4M5I5,
3051CG2A02A1AB3H2L4M5I5, 3051CD5A22A1AB4M5I5,
3051CG3A02A1AB3H2L4M5I5, 3051CA1A02A1AB1H2L4M5,
3051CG4A02A1AB3H2L4M5I5, 3051CA2A02A1AB1H2L4M5,
3051CG5A02A1AB3H2L4M5I5, 3051CA3A02A1AB1H2L4M5,
3051CG1A22A1AB4M5, 3051CA4A02A1AB1H2L4M5,
3051CG2A22A1AB4M5, 3051CA5A02A1AB1H2L4M5,
3051CG3A22A1AB4M5, 3051CA1A02A1AB3H2L4M5,
3051CG4A22A1AB4M5, 3051CA2A02A1AB3H2L4M5,
3051CG5A22A1AB4M5, 3051CA3A02A1AB3H2L4M5,
3051CG1A22A1AB4M5DF, 3051CA4A02A1AB3H2L4M5,
3051CG2A22A1AB4M5DF, 3051CA5A02A1AB3H2L4M5,
3051CG3A22A1AB4M5DF, 3051CA1A02A1AB1H2L4M5K5,
3051CG4A22A1AB4M5DF, 3051CA2A02A1AB1H2L4M5K5,
3051CG5A22A1AB4M5DF 3051CA3A02A1AB1H2L4M5K5,
3051CG1A22A1AB4M5K5, 3051CA4A02A1AB1H2L4M5K5,
3051CG2A22A1AB4M5K5, 3051CA5A02A1AB1H2L4M5K5,
3051CG3A22A1AB4M5K5 3051CA1A02A1AB1H2L4M5E5,
3051CG4A22A1AB4M5K5, 3051CA2A02A1AB1H2L4M5E5,
3051CG5A22A1AB4M5K5, 3051CA3A02A1AB1H2L4M5E5,
3051CG1A22A1AB4M5E5 3051CA4A02A1AB1H2L4M5E5,
3051CG2A22A1AB4M5E5, 3051CA5A02A1AB1H2L4M5E5,
3051CG3A22A1AB4M5E5, 3051CA1A02A1AB1H2L4M5I5,
3051CG4A22A1AB4M5E5 3051CA2A02A1AB1H2L4M5I5,
3051CG5A22A1AB4M5E5, 3051CA3A02A1AB1H2L4M5I5,
3051CG1A22A1AB4M5I5, 3051CA4A02A1AB1H2L4M5I5,
3051CG2A22A1AB4M5I5 3051CA5A02A1AB1H2L4M5I5,
3051CG3A22A1AB4M5I5, 3051CA1A02A1AB3H2L4M5K5,
3051CG4A22A1AB4M5I5, 3051CA2A02A1AB3H2L4M5K5,
3051CG5A22A1AB4M5I5 3051CA3A02A1AB3H2L4M5K5,
3051CD0A02A1AB1H2L4M5, 3051CA4A02A1AB3H2L4M5K5,
3051CD1A02A1AB1H2L4M5, 3051CA5A02A1AB3H2L4M5K5,
3051CD2A02A1AB1H2L4M5 3051CA1A02A1AB3H2L4M5E5,
3051CD3A02A1AB1H2L4M5, 3051CA2A02A1AB3H2L4M5E5,
3051CD4A02A1AB1H2L4M5, 3051CA3A02A1AB3H2L4M5E5,
3051CD5A02A1AB1H2L4M5 3051CA4A02A1AB3H2L4M5E5,
3051CD0A02A1AB3H2L4M5, 3051CA5A02A1AB3H2L4M5E5,
3051CD1A02A1AB3H2L4M5, 3051CA1A02A1AB3H2L4M5I5,
3051CD2A02A1AB3H2L4M5 3051CA2A02A1AB3H2L4M5I5,
3051CD3A02A1AB3H2L4M5, 3051CA3A02A1AB3H2L4M5I5,
3051CD4A02A1AB3H2L4M5, 3051CA4A02A1AB3H2L4M5I5,
3051CD5A02A1AB3H2L4M5 3051CA5A02A1AB3H2L4M5I5,
3051CD0A02A1AB1H2L4M5K5, 3051CA1A22A1AB4M5,
3051CD1A02A1AB1H2L4M5K5, 3051CA2A22A1AB4M5,
3051CD2A02A1AB1H2L4M5K5, 3051CA3A22A1AB4M5,
3051CD3A02A1AB1H2L4M5K5, 3051CA4A22A1AB4M5,
3051CD4A02A1AB1H2L4M5K5, 3051CA5A22A1AB4M5,
3051CD5A02A1AB1H2L4M5K5, 3051CA1A22A1AB4M5DF,
3051CD0A02A1AB1H2L4M5E5, 3051CA2A22A1AB4M5DF,
3051CD1A02A1AB1H2L4M5E5, 3051CA3A22A1AB4M5DF,
3051CD2A02A1AB1H2L4M5E5, 3051CA4A22A1AB4M5DF,
3051CD3A02A1AB1H2L4M5E5, 3051CA5A22A1AB4M5DF,
3051CD4A02A1AB1H2L4M5E5, 3051CA1A22A1AB4M5K5,
3051CD5A02A1AB1H2L4M5E5, 3051CA2A22A1AB4M5K5,
3051CD0A02A1AB1H2L4M5I5, 3051CA3A22A1AB4M5K5,
3051CD1A02A1AB1H2L4M5I5, 3051CA4A22A1AB4M5K5,
3051CD2A02A1AB1H2L4M5I5, 3051CA5A22A1AB4M5K5,
3051CD3A02A1AB1H2L4M5I5, 3051CA1A22A1AB4M5E5,
3051CD4A02A1AB1H2L4M5I5, 3051CA2A22A1AB4M5E5,
3051CD5A02A1AB1H2L4M5I5, 3051CA3A22A1AB4M5E5,
3051CD0A02A1AB3H2L4M5K5, 3051CA4A22A1AB4M5E5,
3051CD1A02A1AB3H2L4M5K5, 3051CA5A22A1AB4M5E5,
3051CD2A02A1AB3H2L4M5K5, 3051CA1A22A1AB4M5I5,
3051CD3A02A1AB3H2L4M5K5, 3051CA2A22A1AB4M5I5,
3051CD4A02A1AB3H2L4M5K5, 3051CA3A22A1AB4M5I5,
3051CD5A02A1AB3H2L4M5K5, 3051CA4A22A1AB4M5I5,

 

Kontaktieren Sie uns jederzeit

86-755-26850710
Wohnung 10, 6/F, Block A, High-Tech Ind. Ctr. 5-21 Pak Tin Par St, Tsuen Wan, Hongkong
Senden Sie Ihre Anfrage direkt an uns